Software

  • Our DNS servers run gdnsd. We use geographical DNS to distribute requests between our seven data centers (3x US, 2x Europe, 1x Asia, 1x South America) depending on the location of the client.
  • We use Linux Virtual Server (LVS) on commodity servers to load balance incoming requests. LVS is also used as an internal load balancer to distribute MediaWiki requests. For back end monitoring and failover, we have our own system called PyBal.
  • For regular MediaWiki web requests (articles/API) we use Varnish and Apache Traffic Server caching proxy servers in front of Apache HTTP Server.
  • All our servers run Debian GNU/Linux.
  • For distributed object storage we use Swift.
  • Our main web application is MediaWiki, which is written in PHP (~70 %) and JavaScript (~30 %).[1]
  • Our structured data is stored in MariaDB since 2013.[2] We group wikis into clusters, and each cluster is served by several MariaDB servers, replicated in a single-master configuration.
  • We use Memcached for caching of database query and computation results.
  • For full-text search we use Elasticsearch (Extension:CirrusSearch).
  • https://noc.wikimedia.org/ – Wikimedia configuration files.
 
Wikimedia server racks at CyrusOne

Alojamento

As of abril de 2024, we have the following colocation facilities (each name except for Magru is derived from an acronym of the facility’s company and an acronym of a nearby airport):

eqiad
Application services (primary) at Equinix in Ashburn, Virginia (Washington, DC area).
codfw
Application services (secondary) at CyrusOne in Carrollton, Texas (Dallas-Fort Worth area).
esams
Caching at EvoSwitch in Amsterdam, the Netherlands.[3]
ulsfo
Caching at United Layer in San Francisco.
eqsin
Caching at Equinix in Singapore.
drmrs
Caching at Digital Realty in Marseille.
magru
Caching in São Paulo, Brazil.

História

The backend web and database servers are in Ashburn, with Carrollton to handle emergency fallback in the future. Carrollton was chosen for this as a result of the 2013 Datacenter RfC. At EvoSwitch, we have a Varnish cache cluster and several miscellaneous servers. The Kennisnet location is now used only for network access and routing.

Ashburn (eqiad) became the primary data center in January 2013, taking over from Tampa (pmtpa and sdtpa) which had been the main data centre since 2004. Around April 2014, sdtpa (Equinix – formerly Switch and Data – in Tampa, Florida, provided networking for pmtpa) was shut down, followed by pmtpa (Hostway – formerly PowerMedium – in Tampa, Florida) in October 2014.

In the past we've had other caching locations like Seoul (yaseo, Yahoo!) and Paris (lopar, Lost Oasis); the WMF 2010–2015 strategic plan reach target states: "additional caching centers in key locations to manage increased traffic from Latin America, Asia and the Middle East, as well as to ensure reasonable and consistent load times no matter where a reader is located."

EvoSwitch and Kennisnet are recognised as benefactors for their in-kind donations. See the current list of benefactors.

A list of servers and their functions used to be available at the server roles page; no such list is currently maintained publicly (perhaps the private racktables tool has one). It used to be possible to see a compact table of all servers grouped by type on icinga, but this is no longer publicly available. However, the puppet configuration provides a pretty good reference for the software that each server runs.

B-roll of servers in Texas in 2015

Estado e monitorização

You can check one of the following sites if you want to know if the Wikimedia servers are overloaded, or if you just want to see how they are doing.

If you are seeing errors in real time, visit #wikimedia-techConecte-se on irc.libera.chat. Check the topic to see if someone is already looking into the problem you are having. If not, please report your problem to the channel. It would be helpful if you could report specific symptoms, including the exact text of any error messages, what you were doing right before the error, and what server(s) are generating the error, if you can tell.

Utilização de energia

In 2017, the WMF board of trustees adopted a resolution containing a commitment to minimize the Foundation's overall environmental impact, especially around data centres through using green energy. The community-led Sustainability Initiative, created in 2015, aims at reducing the environmental impact of the servers by calling for renewable energy to power them.

The Wikimedia Foundation's servers are spread out in five colocation data centers in Virginia, Texas and San Francisco in the United States, Amsterdam and Marseille in Europe, and Singapore in Asia.

In 2021, the servers used 358.8 kW (kilowatts), summing up to about 3.143 GW h (gigawatt hours) of electrical energy per year. The total carbon footprint of the servers was 1,073 metric tons CO2-eq in 2021.[4]

Only the few servers in Amsterdam and in Marseille run on renewable energy, the other use different conventional energy mixes. In 2016, just 9% of Wikimedia Foundation data centers' energy came from renewable sources, with the rest split evenly between coal, gas and nuclear power (34%, 28%, and 28%, respectively). The bulk of the Wikimedia Foundation's electricity demand is in Virginia and Texas, which have both very fossil fuel heavy grids.

Server name Data center location Provider Date opened Average energy consumption (kW) Energy sources Carbon footprint (CO2/year) Renewable option and cost
eqiad Ashburn, VA

20146-20149 USA

Equinix (Website)
February 2011 May 2016: 130

May 2015: 152

2016:
32% coal

20% natural gas

25% nuclear

17% renewable

1,040,000 lb = 520 short tons = 470 metric tons = 0.32 * 130 kW * 8765.76 hr/yr * 2.1 lb CO2/kWh for coal

+ 0.20 * 130 kW * 8765.76 hr/yr * 1.22lb CO2/kWh for nat gas

+ 0.25 * 130 kW * 8765.76 hr/yr * 0 lb CO2/kWh for nuclear

+ 0.17 * 130 kW * 8765.76 hr/yr * 0 lb CO2/kWh for renewable

In 2015, Equinix made "a long-term commitment to use 100 percent clean and renewable energy". In 2017, Equinix renewed this pledge.
codfw Carrollton, TX

75007 USA

CyrusOne (Website)
May 2014 May 2016: 77

May 2015: 70

2016:
23% coal

56% natural gas

6% nuclear

1% hydro/biomass/solar/other

14% wind (Oncor/Ercot)

790,000 lb = 400 short tons = 360 metric tons = 0.23 * 77 kW * 8765.76 hr/yr * 2.1 lb CO2/kWh for coal

+ 0.56 * 77 kW * 8765.76 hr/yr * 1.22lb CO2/kWh for nat gas

+ 0.06 * 77 kW * 8765.76 hr/yr * 0 lb CO2/kWh for nuclear

+ 0.15 * 77 kW * 8765.76 hr/yr * 0 lb CO2/kWh for renewables

?
esams Haarlem

2031 BE Netherlands

EvoSwitch (Website)
Dezembro de 2008 Maio de 2016: < 10

Maio de 2015: 10

"a combination of wind power, hydro and biomass" 0 n.a.
ulsfo San Francisco, CA

94124 USA

UnitedLayer (Website)
June 2012 May 2016: < 5

May 2015: < 5

25% gás natural

23% nuclear

30% renováveis

6% hidroelétrico

17% unspecified (PG&E)

13,000 lb = 6.7 short tons = 6.1 metric tons (+ unspecified) = 0.00 * 5 kW * 8765.76 hr/yr * 2.1 lb CO2/kWh for coal

+ 0.25 * 5 kW * 8765.76 hr/yr * 1.22lb CO2/kWh for nat gas

+ 0.23 * 5 kW * 8765.76 hr/yr * 0 lb CO2/kWh for nuclear

+ 0.36 * 5 kW * 8765.76 hr/yr * 0 lb CO2/kWh for hydro/renewable

+ 0.17 * 5 kW * 8765.76 hr/yr * ? lb CO2/kWh for unspecified

?
eqsin Singapore Equinix (Site da Web) ? ? ? ? ?
drmrs Marseille Digital Realty (Website) ? ? ? ? ?

Consulte também

Mais informação de hardware

  • wikitech:Clusters – technical and usually more up-to-date information on the Wikimedia clusters

Registos de administração

Páginas de tráfego off-site

Informação histórica

Referências

  1. See MediaWiki analysis, MediaWiki WMF-supported extensions analysis.
  2. "Wikipedia Adopts MariaDB" (text/html). blog.wikimedia.org. Wikimedia Foundation, Inc. 2013-04-22. Retrieved 2014-07-20. 
  3. Suffered a major DoS attack on September 6/7, 2019. See dedicated article on WMF website.